Subscribe to process signals: SIGINT, SIGTERM, SIGHUP, SIGUSR1, SIGUSR2.

Text
import nox.signal

Capability: process.

The handler does exactly one async-signal-safe thing: it sets a flag. Your code reads the flag from its own task, so a signal never interrupts Nox code in the middle of a statement. A typical graceful-shutdown loop:

Text
nox.signal.install(nox.signal.sigterm())
while not nox.signal.take(nox.signal.sigterm()):
    ...do work...
    nox.time.sleep_ms(50)     # inside a task this suspends only that task
...drain active work and exit...
Function Description
sigint(), sigterm(), sighup(), sigusr1(), sigusr2() the platform's signal number (0 where signals do not exist)
install(sig) routes the signal to the flag-setting handler; True on success
pending(sig) is the flag set? (does not clear it)
take(sig) reads and clears the flag: True once per delivered signal
wait(sig, timeout_ms) cooperatively waits until the signal arrives or the timeout expires; True if it arrived (and clears the flag)
send_self(sig) sends the signal to this process (tests, self-shutdown)
service_run(name) Windows: connect to the Service Control Manager when started as a service (True), False in a console / on other systems; see Notes
service_stopped(code) Windows service: report SERVICE_STOPPED before exiting (code != 0: service-specific exit code)
Nox
import nox.signal

s: int = nox.signal.sigusr1()
print(nox.signal.install(s))
print(nox.signal.send_self(s))
print(nox.signal.take(s), nox.signal.take(s))
Output
True
True
True False

Notes#

  • Windows has no POSIX signals but has console events, and nox.signal maps them: sigint() (2) is Ctrl+C, sigterm() (15) is Ctrl+Break, closing the console, logging off and shutting down. install, pending, take, wait and send_self work as on POSIX, so a while not take(sigterm()) loop is portable. Windows ends the process about 5 seconds after the handler returns for close/logoff/shutdown events: finish draining within that time. sigusr1()/sigusr2() do not exist there (0), a process without a console receives no events, and stopping a Windows service needs service_run (see below). nox.http.serve* shuts down gracefully on the same events.
  • WebAssembly (wasm32-freestanding --asyncify): the host delivers a stop request. The module exports nox_host_signal(sig); the host calls it with 2 (SIGINT), 15 (SIGTERM) or 1 (SIGHUP) and gets 1 if the module had installed that signal (the flag is set) or 0 if not (the host then applies its default, e.g. ends the process). sigint()/sigterm()/sighup() are 2/15/1, sigusr1()/sigusr2() are 0, send_self works on installed signals. wait suspends the whole program on a host timer (capability bit 16) so the host's event loop keeps running and can deliver the signal; a host that does not grant the timer blocks as before. With the Node command line (node wasm_host.mjs prog.wasm) Ctrl+C/kill are delivered this way; an embedder passes runNox(bytes, io, { signalSource: (deliver) => { ...; return stop; } }). No new nox_host import is needed. wasm32-wasi, plain freestanding and --threads modules, and non-WASM freestanding targets have no signals: install returns False, take/pending always False.
  • nox.http.serve* installs its own SIGTERM/SIGINT handler when it starts; the last installer wins, so do not combine the two on the same signal. Use nox.http.shutdown() to stop a server from code.
  • Signal numbers differ between platforms (SIGUSR1 is 10 on Linux and 30 on macOS), which is why they come from functions rather than constants.
  • Windows services (SCM): service_run(name) connects a program started by the Service Control Manager: it returns True when it is running as a service and False in a console (or on other systems), so one binary works both ways. Call it once at the start; Nox code never runs on the SCM's threads. sc stop and a system shutdown then look like SIGTERM (wait(sigterm(), ms) / take(sigterm())), and when the program has finished it must call service_stopped(code) (non-zero code is reported as the service-specific exit code), otherwise the SCM treats the process as having ended unexpectedly. Wrapper tools such as NSSM or WinSW still work and need no code. The console fallback is covered by a real-Windows run; the SCM path is verified with scripts/windows_service_probe.bat (it installs a service, so run it only on your own development machine).